Chamber Furnaces for Thermal Cleaning Electrically Heated or Gas-Fired
  
  
PRODUCT IMAGE

1 Exhaust gas 2 ignition flame 3 fresh-air

PRODUCT IMAGE

N 300 BO with safety torch

The chamber furnaces of the model series N .. BO are used for thermal cleaning of components. Examples include the removing residual wax of pouring clusters inclusive subsequent sintering or the thermal cleaning of oxide catalytic honey combs from carbon black or fuel residues. The furnaces are electrically heated or gas-fired. The electrically heated furnaces, for safety reasons, have an integrated gas torch for igniting hazardous gas concentrations. The generation of combustible mixtures is avoided and their safe burning off is ensured.

The furnace series is suitable for products that will not be damaged by a temporary, uncontrolled temperature rise.

The burning of unwanted organic ingrediants can take place at temperatures > 400 °C. Following this, a subsequent process can take place up to max. 1000 °C or 1400 °C (electrically) or 1000 °C (gas-fired).

For safety, the furnace door locks after the program was started and cannot be opened again until the temperature has dropped below a defined value. In case of burner malfunction or gas shortage the process is aborted.

Models N 100 BO - N 650/14 BO, electrically heated

  • Tmax 1000 °C or 1400 °C
  • Standard sizes up to 650 liters furnace chamber, additional sizes on request
  • Exhaust hood
  • Fully automatic temperature control
  • Optional thermal afterburning
  • Defined application within the constraints of the operating instructions

Models NB 300 BO and NB 650 BO, gas-fired

  • Tmax 1000 °C
  • Standard sizes up to 650 liters furnace chamber, additional sizes on request
  • Integrated thermal afterburning
  • Defined application within the constraints of the operating instructions
Model TmaxInner dimensions in mm Outer dimensions in mm Heating power
 °CwdhWDHin kW1
N 100 BO10004005304601200130021009
N 300 BO100055070078013501450220020
N 300/14 BO140055070078013501450220030
N 650/14 BO1400700850110017001900270062
1Depending on furnace design connected load might be higher
Model TmaxInner dimensions in mm Outer dimensions in mmOutput burner
 °CwdhWDHin kW
 
NB 300 BO1000550700780125016503000100
NB 650 BO10007008501100160021003150200